everflo oxygen concentrator manual pdf

The EverFlo Oxygen Concentrator is a reliable device designed to deliver concentrated oxygen from room air for low-flow oxygen therapy, ideal for home use and patient comfort.

Technical Specifications

The EverFlo Oxygen Concentrator offers precise technical specifications, including maximum oxygen concentration levels, adjustable flow rates, compact design, and quiet operation, ensuring reliable performance for oxygen therapy needs.

2.1 Oxygen Concentration Levels

The EverFlo Oxygen Concentrator delivers oxygen with a concentration level of 93% or higher at all flow settings, ensuring consistent and reliable oxygen therapy. It operates within the strict guidelines set by ISO standards, maintaining purity levels necessary for patient safety. The device is designed to alert users if oxygen concentration drops below acceptable levels, ensuring continuous monitoring. This feature guarantees that patients receive the prescribed oxygen levels without compromise, making it a dependable choice for home oxygen therapy. The concentration levels are carefully regulated to meet the needs of patients requiring supplemental oxygen, providing peace of mind for both users and caregivers.

2.2 Flow Rate and Settings

The EverFlo Oxygen Concentrator offers a continuous flow rate of 0.5 to 5 liters per minute (LPM), providing flexibility to meet varying patient needs. The flow rate is adjustable in increments of 0.5 LPM, allowing precise settings tailored to individual prescriptions. It is essential to set the flow rate as prescribed by a healthcare professional, as improper settings may compromise therapy effectiveness. The device maintains a maximum flow rate of 5 LPM, suitable for low-flow oxygen therapy requirements. When connected to the UltraFill Oxygen Filling Station, the flow rate is reduced to 3 LPM to ensure compatibility and safe operation. Always follow the manual guidelines for accurate flow rate adjustments.

2.3 Dimensions and Weight

The EverFlo Oxygen Concentrator is designed with a compact and durable structure, measuring 23.5 inches in height, 15.5 inches in width, and 9.5 inches in depth. Weighing approximately 52 pounds (23.6 kilograms), it is lightweight enough for easy placement in home environments while maintaining stability. The unit’s dimensions and weight ensure it does not occupy excessive space, making it ideal for use in various settings. Its portability and manageable size contribute to patient comfort and convenience. The EverFlo is constructed to be both durable and user-friendly, ensuring reliable performance while maintaining a compact footprint for everyday use.

2.4 Power Requirements

The EverFlo Oxygen Concentrator operates on standard household electricity, requiring a power input of 120 volts AC, 60 Hz. It is designed to be energy-efficient, drawing approximately 2.8 amps during normal operation. The device is compatible with most home electrical systems, making it convenient for continuous use. It is important to ensure the concentrator is plugged directly into a dedicated electrical outlet to avoid power interruptions. The EverFlo is equipped to handle minor power fluctuations but should not be used with generators or unstable power sources. Always follow the power requirements outlined in the user manual for safe and reliable operation.

2.5 Noise Levels

The EverFlo Oxygen Concentrator is designed to operate quietly, making it suitable for home use. It produces a sound level of approximately 40 dBA, which is comparable to a quiet conversation. This low noise level ensures minimal disruption to daily activities, providing a comfortable environment for patients. The device’s compact design and efficient airflow system contribute to its quiet operation. Proper placement, as outlined in the manual, can further optimize noise reduction. Users are advised to keep the concentrator at least 6 inches away from walls or curtains to ensure proper airflow and maintain its low noise output. This feature enhances overall patient satisfaction and ease of use.

Intended Use

The EverFlo Oxygen Concentrator is designed to provide supplemental oxygen to individuals requiring low-flow oxygen therapy. It is not intended for life-support or life-sustaining purposes. The device operates by concentrating oxygen from room air, delivering it to patients through a prescribed flow rate set by their healthcare provider. Patients should not adjust the flow settings without professional guidance, as this can impact the effectiveness of their oxygen therapy. The EverFlo is suitable for home use, offering a reliable and convenient solution for those needing supplemental oxygen. Always use the device in accordance with the recommendations outlined in the user manual for optimal performance and safety.

Safety Precautions

The EverFlo Oxygen Concentrator should not be placed in small, closed spaces or covered. Avoid removing the device’s covers, as this can compromise safety and functionality. Always follow the user manual guidelines to ensure proper and safe operation.

4.1 General Warnings

The EverFlo Oxygen Concentrator must not be placed in small, enclosed spaces or covered, as this can impair its function. Users should never remove the device’s covers, as this may expose internal components and pose safety risks. The concentrator should not be used near open flames, sparks, or high heat sources, as oxygen is highly flammable. Additionally, the device is not intended for life-support or life-sustaining therapy. Always adhere to the guidelines provided in the user manual to ensure safe and effective operation. Misuse or modification of the device can lead to serious injury or equipment malfunction. Proper precautions help maintain user safety and device performance.

4.2 Specific Cautions

When using the EverFlo Oxygen Concentrator, ensure it is placed in a well-ventilated area, away from direct sunlight and high humidity. Avoid placing the device near curtains, bedding, or flammable materials, as oxygen increases fire risk. Do not use aerosol products or smoke near the concentrator. Always follow the user manual guidelines for operation and maintenance. Never modify or tamper with the device, as this can lead to malfunction or safety hazards. Keep the concentrator out of reach of children and pets. Regularly inspect the power cord and tubing for damage. Proper usage and adherence to these cautions ensure safe and effective therapy.

4.3 Proper Placement Guidelines

The EverFlo Oxygen Concentrator should be placed in a well-ventilated, dry area, away from direct sunlight and high humidity. Position the device on a stable, flat surface to ensure proper operation. Maintain at least 12 inches of clearance from walls, furniture, and bedding to allow adequate airflow. Avoid placing the concentrator in small, enclosed spaces like closets or under beds, as this can impede ventilation. Keep it away from flammable materials, aerosol products, and open flames, as oxygen increases fire risks. Do not cover the device with towels, blankets, or other materials, as this can trap heat and cause malfunction. Proper placement ensures safe and efficient oxygen delivery.

Operating Instructions

Read the entire manual before use to understand the device’s operation. Turn on the concentrator, ensure the flow setting matches your prescription, and connect the tubing. Regularly clean and maintain the device as instructed. Always follow guidelines for connecting to UltraFill and adjusting settings. Proper operation ensures safe and effective oxygen therapy.

5.1 Initial Setup

To set up the EverFlo Oxygen Concentrator, place it on a flat, stable surface in a well-ventilated area, ensuring at least 12 inches of clearance from walls. Plug the power cord into a grounded electrical outlet. Set the flow rate as prescribed by your healthcare provider using the flow control knob. Attach the nasal cannula or oxygen tubing to the outlet port. Ensure the device is turned off before connecting or disconnecting any components. Allow the concentrator to run for 5 minutes before use to ensure proper operation. Refer to the manual for detailed instructions and safety guidelines. Always follow healthcare provider recommendations.

5.2 Daily Use Guidelines

For optimal performance, place the EverFlo Oxygen Concentrator in a well-ventilated area, away from direct sunlight and moisture. Ensure the device is on a flat, stable surface with adequate clearance. Turn on the concentrator and allow it to run for 5 minutes before use. Set the flow rate as prescribed by your healthcare provider, using the flow control knob. Regularly inspect the tubing and nasal cannula for damage or kinks. Clean the exterior with a soft, damp cloth, avoiding harsh chemicals. Always monitor the flow rate and listen for alarms, which indicate issues like low oxygen levels or high flow. Refer to the manual for troubleshooting and maintenance tips; Follow all safety precautions to ensure safe and effective oxygen therapy.

5.3 Adjusting Flow Settings

The EverFlo Oxygen Concentrator flow settings should only be adjusted by a healthcare professional based on your specific needs. To change the flow rate, locate the flow control knob on the front of the device. Turn the knob clockwise or counterclockwise to increase or decrease the flow, ensuring it matches the prescribed setting; The device delivers oxygen in increments of 0;5 to 5 liters per minute (LPM). Always refer to the manual for precise instructions. Note: Do not adjust the flow settings without consulting your healthcare provider, as incorrect settings may pose health risks. Monitor the device for alarms, which indicate issues like low oxygen levels or high flow.

5.4 Connecting to UltraFill

To connect the EverFlo Oxygen Concentrator to the UltraFill Oxygen Filling Station, ensure both devices are powered off. Attach the oxygen tubing from the UltraFill to the EverFlo’s oxygen outlet. Turn on the UltraFill and set the desired flow rate. Note: When connected, the EverFlo’s maximum flow rate will reduce from 5 LPM to 3 LPM. The device will disable high flow and no-flow alarms during this connection. Always follow the manual for proper setup and operation. Consult your healthcare provider before connecting to ensure compatibility with your oxygen therapy needs. Proper connection ensures safe and efficient oxygen delivery.

Maintenance and Care

Regularly clean the EverFlo Oxygen Concentrator with a soft, damp cloth to prevent dust buildup. Check and replace filters as recommended in the manual for optimal performance.

6.1 Cleaning

Regular cleaning is essential to maintain the EverFlo Oxygen Concentrator’s performance and hygiene. Use a soft, damp cloth to wipe down the exterior, ensuring no moisture enters the vents or internal components. Avoid using harsh chemicals, abrasive cleaners, or submerging any part in water. Clean the nasal cannula and mask regularly according to the manufacturer’s instructions. Do not remove any internal components, as this may void the warranty or compromise safety. Refer to the manual for specific cleaning guidelines to ensure proper maintenance and functionality of the device. Cleaning helps prevent dust buildup and ensures reliable oxygen delivery.

6.2 Filter Replacement

The EverFlo Oxygen Concentrator requires regular filter replacement to ensure optimal performance and oxygen purity. The pre-filter should be replaced every 1 to 2 years, depending on usage, as specified in the manual. Internal filters are not user-serviceable and should only be replaced by authorized personnel. Cleaning the filters is not recommended, as this may damage the components. Refer to the manual for detailed instructions on when and how to replace filters. Proper filter maintenance ensures the device delivers high-quality oxygen and operates efficiently. Always follow the manufacturer’s guidelines to maintain warranty validity and safety standards.

Troubleshooting Common Issues

The EverFlo Oxygen Concentrator may experience issues like alarms, low oxygen levels, or flow problems. Always refer to the manual for solutions, such as checking power connections or ensuring proper device placement.

7.1 Common Issues

The EverFlo Oxygen Concentrator may encounter issues such as low oxygen concentration, high-pitched noises, or alarm activations. These problems often arise from improper placement, blocked air filters, or power supply disruptions. Users may also experience reduced flow rates, especially when connected to the UltraFill system, which limits delivery to 3 LPM. Additionally, malfunction indicators or persistent alarms can signal internal issues requiring professional attention. Regular maintenance, such as cleaning filters and ensuring proper ventilation, can help mitigate these problems. Always consult the manual for detailed troubleshooting guidance to address these common issues effectively and ensure optimal device performance.

7.2 Solutions

To address common issues with the EverFlo Oxygen Concentrator, ensure proper placement in a well-ventilated area and check for blockages in air filters or intakes. For low oxygen concentration, verify the power supply and flow settings, consulting your healthcare provider if adjustments are needed. High-pitched noises may indicate dirty or obstructed filters, which should be cleaned or replaced as per the manual. If alarms activate, reset the device and ensure all connections are secure. For reduced flow rates when connected to UltraFill, refer to the manual for flow adjustment guidance. Regular maintenance and adhering to troubleshooting steps can resolve most issues effectively.

Alarm Systems and Alerts

The EverFlo Oxygen Concentrator features a robust alarm system to ensure patient safety and device functionality. Alarms activate in response to low oxygen levels, power failures, or device malfunctions. Visual and audible alerts notify users of issues, such as high-pitched noises or flashing indicators. The manual outlines specific alarm conditions, including low flow, high flow, and oxygen concentration alerts. Users should address alarms promptly by checking power connections, ensuring proper ventilation, and verifying flow settings. Referencing the manual is crucial for understanding and resolving alarm-related issues effectively. Regular maintenance and adherence to guidelines can help minimize alarm occurrences and ensure reliable operation.

Frequently Asked Questions

Q: Can I adjust the flow settings on my own?
A: No, flow settings should only be changed by a healthcare professional to ensure safe and effective oxygen therapy.

Q: How often should I clean the concentrator?
A: Regular cleaning with a soft, damp cloth is recommended to maintain hygiene and performance.

Q: Can I use the EverFlo while it’s charging?
A: Yes, the device can operate while connected to a power source, but ensure it’s placed in a well-ventilated area.

Q: What if the alarm sounds?
A: Refer to the manual to identify the cause, such as low oxygen levels or power issues, and take appropriate action.

Q: Is the EverFlo portable?
A: While compact, it’s designed for home use and should not be moved frequently during operation.
These FAQs address common user concerns, ensuring safe and effective use of the EverFlo Oxygen Concentrator. Always consult the manual for detailed guidance.
The EverFlo Oxygen Concentrator is a reliable and user-friendly device designed to provide supplemental oxygen therapy in the comfort of your home. Its compact design and efficient operation make it an ideal choice for patients requiring low-flow oxygen. By following the guidelines in the manual, users can ensure safe and effective use. Regular maintenance and adherence to safety precautions are essential to prolong the device’s lifespan and performance. For optimal results, always consult your healthcare provider for personalized settings and advice. This concludes our comprehensive overview of the EverFlo Oxygen Concentrator, emphasizing its benefits and proper usage.

References

The information provided in this article is based on the official Philips Respironics EverFlo Oxygen Concentrator User Manual. For detailed instructions and technical specifications, refer to the PDF manual. Additional resources, including troubleshooting guides and FAQs, can be found on the Philips Respironics support page. Always consult your healthcare provider for personalized advice on using the EverFlo Oxygen Concentrator. This concludes the references section.

Leave a Reply